01
Camera Inspection
We run an inspection camera down the flue and record what the clay flue tile, smoke chamber, and damper look like. You see the footage. If the tile is sound and the problem is just creosote, we tell you that and clean instead of selling a liner. This step takes 30 to 45 minutes.
02
Sizing and Quote
We measure the flue collar on your appliance, count the flue's height and offsets, and match the liner to the appliance's BTU output. You get a written price before we start. Most Galloway jobs land between $2,400 and $5,800 depending on height, liner grade, and whether insulation wrap is needed.
03
Flue Prep and Sweep
Before any liner goes in, we sweep the flue with a chimney brush and rods to strip loose creosote and debris. A creosote sweeping log may go in afterward on wood-burning setups to keep the flue conditioned. Clean walls mean the insulation wrap seats evenly and the liner does not snag on a ledge.
04
Liner Installation
We pull the insulated stainless liner down from the top, seat it into the smoke chamber, and connect it at the appliance or damper with the correct adapter. A damper clamp holds the plate in place. The top gets a cap and a stainless top plate sealed against water intrusion. This is the two to four hour stretch.
05
Test and Documentation
We light a test fire, watch the draft, and check every joint for leakage. Then we hand you photos of the before and after, the liner spec sheet, and the warranty paperwork. If anything reads wrong on the draft test, we correct it before we leave the driveway.